Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Medical Journal ; (24): 1327-1332, 2017.
Article in English | WPRIM | ID: wpr-330621

ABSTRACT

<p><b>BACKGROUND</b>The autologous saphenous vein is the most common conduit for coronary artery bypass grafting, but the vein graft disease will occur. This study used Matrigel basement membrane matrix with many different growth factors to promote vasa vasorum neovascularization and extenuate the hypoxia to improve remodeling.</p><p><b>METHODS</b>This study observed the hypoxia and thickness of the vein grafts at different times. Normal veins and vein grafts with 15 min of ischemia one day postoperatively were harvested in the neck of rabbits. Paired vein grafts with 15 min ischemia bilaterally (control vs. Matrigel basement membrane matrix) were performed and harvested at 2, 6, and 12 weeks postoperatively. The rabbits were randomly divided into four postoperative groups (six rabbits in each group): Group 1, one day postoperatively; Group 2, 2 weeks postoperatively; Group 3, 6 weeks postoperatively; and Group 4, 12 weeks postoperatively. The dimensions of vessel wall were captured, and the mean thicknesses of intima, media, and adventitia were measured. The hypoxia-inducible factor (HIF)-1α and HIF-2α labeling indices of intima, media, and adventitia were also measured.</p><p><b>RESULTS</b>In Group 1, the labeling index of HIF-1α was high in the normal vein and decreased significantly in the vein graft one day postoperatively (intima: 80 ± 3% vs. 12 ± 1%, P = 0.01; media: 67 ± 5% vs. 11 ± 1%, P = 0.01; adventitia: 40 ± 10% vs. 7 ± 2%, P = 0.03). The labeling index of HIF-2α had similar trend as HIF-1α (intima: 80 ± 10% vs. 10 ± 5%, P = 0.02; media: 60 ± 14% vs. 12 ± 2%, P = 0.01; adventitia: 45 ± 20% vs. 10 ± 4%, P = 0.03). Compared with the control vein grafts, vein grafts with Matrigel basement membrane matrix had lower labeling indices of HIF-1α and HIF-2α in media and adventitia at Group 2 (HIF-1α: 34 ± 5% vs. 20 ± 4%, P = 0.04 for media; 23 ± 3% vs. 11 ± 2%, P = 0.03 for adventitia; HIF-2α: 37 ± 6% vs. 21 ± 4%, P = 0.03 for media; 24 ± 4% vs. 13 ± 2%, P = 0.04 for adventitia) and Group 3 (HIF-1α: 33 ± 4% vs. 7 ± 2%, P = 0.04 for media; 13 ± 3% vs. 3 ± 1%, P = 0.02 for adventitia; HIF-2α: 27 ± 4% vs. 12 ± 3%, P = 0.02 for media; 19 ± 2% vs. 6 ± 1%, P = 0.02 for adventitia). There were no differences in mean thickness of intima, media, and adventitia between bilateral vein grafts at 2, 6, and 12 weeks postoperatively.</p><p><b>CONCLUSIONS</b>This study indicated that promoting vasa vasorum neovascularization of vein grafts extenuated hypoxia, but did not influence the intimal hyperplasia of the wall.</p>


Subject(s)
Animals , Rabbits , Basic Helix-Loop-Helix Transcription Factors , Metabolism , Hyperplasia , Pathology , Hypoxia-Inducible Factor 1 , Metabolism , Hypoxia-Inducible Factor 1, alpha Subunit , Metabolism , Neovascularization, Pathologic , Pathology , Postoperative Period , Saphenous Vein , Pathology , Tunica Intima , Pathology , Vasa Vasorum , Pathology
2.
Chinese Medical Journal ; (24): 2264-2267, 2007.
Article in English | WPRIM | ID: wpr-255800

ABSTRACT

<p><b>BACKGROUND</b>External stents have been used to reduce intimal hyperplasia of vein grafts. The aim of the present study was to define the size of an external stent appropriate for a particular graft by comparing vein grafts with different sizes of external stents.</p><p><b>METHODS</b>A series of paired trials was performed to compare femoral vein grafts with different sizes of external stents, where 30 modeled canines were equally divided into three groups: 6-mm external stent vs non-stent control, 4-mm vs 6-mm external stent, and 4-mm vs 8-mm external stent. At day 3 after operation, color Doppler flow imaging (CDFI) was done to observe blood flow in the lumen. Four weeks later, CDFI was re-checked and the veins were harvested, stained and measured.</p><p><b>RESULTS</b>All grafts were patent without formation of thrombosis. External stents significantly reduced intimal thickness of the vein grafts with a 6-mm external stent compared with the vein grafts without external stents (P < 0.05). The vein grafts with the 4-mm external stent had similar intimal, medial and adventitial thicknesses compared with those with the 6-mm external stent and the 8-mm external stent.</p><p><b>CONCLUSIONS</b>External stents can reduce intimal hyperplasia of vein grafts. Stents of different diameters exert the similar effect on prevention of intimal hyperplasia.</p>


Subject(s)
Animals , Dogs , Aspirin , Therapeutic Uses , Femoral Vein , Transplantation , Hyperplasia , Stents , Tunica Intima , Pathology , Ultrasonography, Doppler, Color
SELECTION OF CITATIONS
SEARCH DETAIL